Articles tagged with: vent replacement
leak sources, Roof Assessments, roof damage »
leak sources, Roof Assessments, roof damage »
leak sources, Roof Assessments »
There was an exhaust vent that was installed broken. It appears as if the vent had been sitting and the plastic had deteriorated and turned brittle and when nails were put in it the flashing cracked and allowing in water. Removed this vent and installed a new 4 inch black exhaust vent. Sealed the flashing on a 3 inch exhaust pipe flashing that was allowing in water. Also, beside these two spots was a chimney that was allowing in a bit of water – sealed the flashing and where the …
leak sources, Roof Assessments »
A section of shingles is missing, ten shingles in one area were missing due to wind damage.
We removed the excess tabs that were ripped and removed some hip and ridge shingles.
We applied roof cement to the area and installed new shingles. We also applied roof cement where the old shingles met the new shingles as well as under the shingle tabs so they cant lift up again with the wind.
We inspected roof surface
There are six attic vents on roof, two of these should be exhaust vents and have incorrect vents …
water leaks »
W e had to remove 3 attic vents. At the homeowners request two of these vents were removed permanently and these areas were shingled over. They had had very small ineffective holes in the roof deck for these two vents.
The third roof vent was correctly reinstalled using roof cement and nails to ensure it is water tight.
We then sealed the exhaust pipe coming out of chimney.
We had to replace missing / damaged shingles in area of chimney due to animal damage.
We also removed the hip and ridge shingles along main …
Roof Assessments, Roof Tune Up »
leak sources, Roof Assessments, water leaks »
The roof leaks from multiple areas. There are 2 vents and a plumbing stack over the bathrooms that are leaking along with the shingles. There are also shingles in the valley area leaking.
We had to completely change out the 2 vents and replaced it with 4 inch flapper vents and redid plumbing stack flashing. We also sealed many shingles along the valley.